SP2xxx: Drum
SM 5-39 D017/D018/D019/D020
Service
Tables
Brake Time
3
Adjusts the length of time of braking to stop reverse rotation of the drum.
[0 to 99/60/1]
This SP is adjusted in units of 6 ms (1 step = 6 ms, 2 steps = 12 ms, etc.)
If "0" is selected, the drum stops reverse rotation immediately.
Note: Adjust the SP only if the PCU makes noise during braking when the
drum rotation slows. To reduce or eliminate the noise, select a lower setting
to reduce the braking time.