The BCU detected a right scanner fan lock signal 5 sec. after the machine was
switched on.
If cycling the machine power off/on does not solve the problem:
Left scanner fan harness connection to the IOB loose, broken, defective
Left scanner fan defective
IOB defective
BCU defective
SC186 B
Gray balance adjustment error
The value for gray balance was detected out of range after gray adjustment.
If cycling the machine power off/on does not solve the problem:
Clean the white strip
Clean the CIS glass
Check the following harnesses for loose, broken, or defective connectors:
1. Xe lamp to lamp regulator
2. Lamp regulator to CIS
3. CIS to IPU
4. CIS to IPU
5. IPU to IOB
One of the following boards is defective
1. CIS
2. IPU
3. IOB
4. BCU
SC191 A
Original exit roller thermistor error
The original exit roller thermistor reading was abnormal.
Thermistor connection loose, broken, defective
Thermistor short
Harness between thermistor and IOB loose, broken, defective
IOB defective
BCU defective