NVRAM, HDD switch error. This error can occur when the NVRAM or the
HDD is removed and installed in another machine.
• Remove the NVRAM and replace it with the original NVRAM.
• Remove the HDD and replace it with the original HDD.
• With the SC code displayed, do SP5832-4 (HDD Formatting - Job Log)
SC876-99 B
Log data error 99
Other errors. .
• Contact the service center if this SC appears
If only the HDD is replaced:
1. Switch off the machine.
2. Remove the HDD, switch the machine on again.
3. Do SP5801-19 (Memory Clear - LCS).
4. Switch off the machine.
5. Reinstall the original HDD and switch on the machine.
6. Do SP5832-4 (HDD Formatting - Job Log).
7. Cycle the machine off/on.
8. Do SP9730-2 and switch it ON (set to "1").
9. Do SP9730-3 and switch it ON (set to "1").
10. Do SP9730-4 and switch it ON (set to "1").
11. Cycle the machine off/on.
SC877 B
Data Overwrite Security SD card error GW
An error occurred, preventing successful execution of the Data Overwrite Security
function, even though it has been set up and enabled.
• DOS card is not inserted completely into the SD card slot
• DOS card has been removed from the SD card slot
• DOS card is damaged.
Note:
• If the SD card has been removed (or was not installed correctly), switch the
machine off, insert the SD card, then switch on the machine again.
• If the SD card has been damaged, procure a new SD card, replace the
NVRAM, then do the DOS option installation.
5. Appendix: Service Call Conditions