SC878 B
TPM electronic authentication error GW
The attempt by the main machine to electronically authenticate TPM failed. When
the machine was switched on the value registered by TPM did not match the value
stored in the USB Flash Memory
Replace the IOB.
SC880 D
File Format Converter (MLB) error GW
A request to get access to the MLB was not answered within the specified time.
MLB defective, replace the MLB
Group 900
SC900 D
Electrical total counter error GW
The total counter contains something that is not a number.
NVRAM incorrect type
NVRAM defective
NVRAM data scrambled
Unexpected error from external source
SC901 D
Mechanical counter error
At the beginning of a count, the machine detected that the mechanical was not
connected.
Note: This function is provided only in EXP machines.
Mechanical counter disconnected
Mechanical counter connector loose or defective
SC910
B
External controller error 1 GW
SC911 External controller error 2 GW
SC912 External controller error 3 GW
SC913 External controller error 4 GW