1916 Fusing Motor Speed Adj. DFU
These SP codes are used to calculate the speed of the fusing motor.
Example: Translucent Paper, Mode 2, 420 mm Roll Paper
• SP1-916-012…1.0% (298∼460 mm Width)
• SP1-916-032…0.5% (Trans. Mode 2)
• SP1-916-051… 0% (Roll)
SP1916-10 to -13 Settings Table
Width (mm) Range Default Step (%)
10 611
-5 to +5
0
0.01
11 461 to 610 0.7
12 298 to 460 1
13 297 Less 1.2
SP1916-21 to -45 Settings Table
Type Mode Range(%) Default(%) Step (%)
21
Plain
1
-5 to +5 0.01 0.01
22 2
23 3
24 4
25 5
31
Trans.
1
-5 to +5 0.5 0.01
32 2
33 3
34 4
35 5
41
Film.
1
-5 to +5 0.5 0.01
42 2
8. Appendix: SP Mode Tables