1
ON Timing: Roll Paper
SP2401-1 to SP2401-3 controls current timing at the leading edge of roll paper, SP2401-5
controls current timing to areas other than the leading edge of roll paper.
[-5 to 30/-5/ 1 mm]
2
ON Timing: Cut Paper
SP2401-2 to SP2401-4 controls current timing at the leading edge of cut sheet paper,
SP2401-5 controls current timing to areas other than the leading edge of cut sheet paper..
[-5 to 30/-5/ 1 mm]
3
Leading Edge: Roll Paper
SP2401-1 to SP2401-3 controls charge timing at the leading edge of roll paper, SP2401-5
controls charge timing to areas other than the leading edge of roll paper.
[10 to 300/100/1 mm]
4
Leading Edge: Cut Paper
This SP sets area outside the image area from the time separation ac/dc goes ON and
switches the separation dc for the leading edge separation.
AC is not reflected. Also, this setting is specific for different types of paper.
• SP2401-2 to SP2401-4 controls current timing at the leading edge of cut sheet paper,
• SP2401-5 controls current timing to areas other than the leading edge of cut sheet
paper.
[10 to 300/100/1 mm]
5
OFF Timing: Roll Paper
This SP sets the OFF timing for ac/dc with roller paper.
Also, ac/dc is done separately, this setting is specific for different types of paper.
• SP2401-1 to SP2401-3 controls charge timing at the leading edge of roll paper
• SP2401-5 controls charge timing to areas other than the leading edge of roll paper.
[-30 to 30/19/1]
6
OFF Timing: Cut Paper
This SP sets the OFF timing for ac/dc with cut sheets.
Also, ac/dc is done separately, this setting is specific for different types of paper.
• SP2401-2 to SP2401-4 controls current timing at the leading edge of cut sheet paper
System Service Mode