EasyManua.ls Logo

Ricoh DD 4450 - Duct Jam Sensor Adjustment

Ricoh DD 4450
269 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Master Feed
C279 4-44 SM
4.7.7 DUCT JAM SENSOR ADJUSTMENT
Ensures that the sensor detects when a master remains in the duct.
Standard: 0.5 volts (within “+0.1” and “-0.1”volts)
Tools: Circuit tester
Rear cover (
p.4-10 "Rear Cover")
1. Check if a master remains in the duct. If a master remains in the duct, remove the master
from the duct.
2. Connect the terminals of a circuit tester to TP102 and a grounded place (e.g. iron base)
3. Connect the power plug, and turn on the main switch to access SP mode.
4. Select SP6-52 (Duct jam sensor voltage).
5. Press the Print Start key.
6. Measure the voltage with the circuit tester, and turn VR102 until the value becomes between
“-0.1” and “+0.1” volts from the standard value (0.5 volts)
When the voltage cannot be adjusted to the standard value, adjust the threshold level of
the duct jam sensor. (SP6-52: Duct jam sensor voltage)
Standard Value
Master present
Threshold level (SP6-52)
Standard Value
Master not present
Above 2.0V 2.0V 0.5 +-0.1V

Table of Contents