Electrical Component Defects
C279 6-16 SM
6.2.2 SWITCHES
Component Condition Symptom
Front Door Safety Switch
Open
The “open cover” indicator is lit. The “open
cover” LED is on.
Close
Main unit error (“A”,”B”,”C” jam and No
ink) cannot be canceled.
Drum information is not updated even if
drums are exchanged with the main
switch on.
An SC occurs if you make a master.
The Interlock SW (door cover side) is OFF
when the door cover is open, and an SC
will occur when a master is made.
Main Switch OFF The machine does not turn on.
ON
The machine does not turn off.
E-61 is displayed when you shut off the
machine.
Master Making Unit Set Switch
Connect
The “Lower Master Tray is Open” indicator
is lit; even though, the master making unit
is not set. Cannot be canceled.
Open
The “No Master Making Unit” indicators
are lit and cannot be canceled.
Eject Box Set Switch
ON
The master is fed to the eject box, even if
there is no eject box.
OFF
The “No eject box” indicators are lit and
cannot be canceled.
Lower Master Tray Set Switch ON
Master making begins, but the lower
master tray is open, the master vacuum
fans do not pull the master, and E-01 is
displayed.