Electrical Component Defects 
SM  6-15  C279 
ng 
Component  Condition  Symptom 
OFF: No 
reflected 
light 
The “P” jam indicator is lit when paper is 
fed-in from ADF.   
 
ADF Org Exit 
ON: 
reflected 
light 
The “P” jam indicator is lit. 
 
OFF: No 
reflected 
light 
The “P” jam indicator is lit when paper is 
fed-in from ADF.   
 
ADF Org Feed Cover 
Open  The “close the ADF cover” indicator is lit.   
Shorted 
The original is fed, even if the ADF cover 
is open. Therefore the “P” jam indicator is 
lit 
 
ADF Lift Up 
Open 
The Platen Cover is read even if the ADF 
has an original and the ADF is not lifted. 
 
Shorted 
The original is fed, even if the ADF cover 
is open. Therefore the “P” jam indicator is 
lit