Electrical Component Defects 
C279  6-14  SM 
Component  Condition  Symptom 
Thermal Head HP Sensor  increase 
the 
pressure 
E-47 is displayed. 
release 
the 
pressure 
Thermal Head Temperature 
Sensor 
Open 
E-09 is displayed whenever the start 
button is pushed.   
 
Shorted 
E-04 is displayed whenever the start 
button is pushed.   
 
ADF Original Detection 
Open 
The original is fed even if the ADF does 
not have an original. Therefore the “P” 
jam indicator is lit   
The Jam LED is ON. The machine cannot 
shift to the energy-saving mode at the 
correct time. 
 
Shorted 
The Platen Cover is scanned even if    the 
ADF has an original   
Even if the original is set in the ADF in 
energy-saving mode, it cannot return from 
energy-saving mode. 
 
ADF Skew Correction 
ON: 
reflected 
light 
The “P” jam indicator is lit. 
 
OFF: No 
reflected 
light 
The “P” jam indicator is lit when paper is 
fed-in from ADF.   
 
ADF Registration 
ON: 
reflected 
light 
The “P” jam indicator is lit.