EasyManua.ls Logo

Ricoh DD 4450 - Fuse, LED, VR, DIP-SW, and TP Tables; Test Points for MPU and PSU

Ricoh DD 4450
269 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fuse, LED, VR, DIP-SW, AND TP Tables
SM 4-85 C279
Replacement
and
Adjustment
4.14.5 TEST POINTS
MPU
No. Function
TP101
Measures the master end sensor voltage. (
p.4-47 "Master End Sensor
Adjustment")
TP102
Measures the duct jam sensor voltage. (
p.4-44 "Duct Jam Sensor
Adjustment")
TP103
Measures the master edge sensor voltage. (
p.4-45 "Master Edge
Sensor Adjustment")
TP104
Measures the 2nd drum master sensor voltage. (
p.4-46 "2nd Drum
Master Sensor Adjustment")
PSU
No. Function
TP701
TP702
Measures the thermal head voltage. (
p.4-48 "Thermal Head Voltage
Adjustment")

Table of Contents