Covers and Boards 
SM  4-13  C279 
and 
Adjustment 
 
3.  NVRAM [A] 
 
 
  Adjust the master end sensor, duct jam sensor, master edge sensor, and 2nd drum 
master sensor (
Master Feed –p.4-44 "Duct Jam Sensor Adjustment", p.4-45 "Master 
Edge Sensor Adjustment", p.4-46 "2nd Drum Master Sensor Adjustment" and p.4-47 
"Master End Sensor Adjustment") after installing the new MPU. 
  If you install a new RAM, you must do the image adjustments (
p.4-3 "Image 
Adjustment").