COMMISSIONING AND MAINTENANCE
ONLY FOR GITRÈ B/100 MODELS
FAULT CAUSE SOLUTION
The storage cylinder safety valve keeps
opening
Storage cylinder safety valve Check valve setting and efciency
Incorrect DHW circuit pressure Check DHW circuit pressure
DHW circuit expansion vessel
Check the efciency of the expansion
vessel
The DHW pump is not working
DHW pump problem
Check/unseize the pump
Check the electrical connection be-
tween the pump and the control panel
Storage cylinder temperature sensor
problem
Check the positioning of the storage
cylinder temperature sensor
Insufcient domestic hot water
Incorrect pressure in DHW circuit Fit a pressure limiter
Lime scale or deposits in storage cylinder
Check and clean as necessary
Check the setting of the storage cylinder
thermostat
Storage cylinder thermostat
Check the setting of the storage cylinder
thermostat