6 Error messages
MANUAL TME400-VCF · EN08 · July, 01
st
2021
93
E
4
Temperature min/max error
Check the alarm setting for the
temperature.
E
5
Pressure sensor hardware error
Contact RMG service.
E
6
Pressure min/max error
Check the alarm setting for the
pressure.
E
7
Gas equation calculation error
Check the alarm setting for the gas
equation.
Check the parameter entries for the cor-
rect unit and reference to the standard
conditions.
E
8
Flow rate min/max error
Check the alarm setting for the flow
rate.
E
9
X:Y pulse comparison error
Check the alarm setting for the pulse
comparison.
E
10
Max. output pulse error
Check the alarm setting for the max.
output pulse.
E
11
Current output error
Check your power connections. Contact
RMG service in case of uncertainty.
E
12
Error CRC Calibration Parameter
Contact RMG service.
W
101
Warning Battery Capacity low
Please change the battery
H
201
New software version
You have a new firmware version
H
202
Metrology switch open
Metrology switch open
H
203
Code word set
Code word is set