fire alarm device A component of a fire alarm system, not incorporated in the control and
indicating equipment which is used to give a warning of fire — for example a
sounder or visual indicator.
fire alarm receiving station A centre from which the necessary fire protection or fire fighting measures can
be initiated at any time.
fire alarm routing equipment Intermediate equipment which routes an alarm signal from control and
indicating equipment to a fire alarm receiving station.
function block diagram An IEC 61131 language that describes a function between input variables and
output variables. Input and output variables are connected to blocks by
connection lines. See 'limited variability language'.
functional safety The ability of a system to carry out the actions necessary to achieve or to
maintain a safe state for the process and its associated equipment.
G
group A collection of two or three input modules (or two output modules), arranged
together to provide enhanced availability for their respective input or output
channels.
H
hand-held equipment Equipment which is intended to be held in one hand while being operated with
the other hand.
HART HART (Highway Addressable Remote Transducer) is an open protocol for
process control instrumentation. It combines digital signals with analogue
signals to provide field device control and status information. The HART
protocol also provides diagnostic data. (For more details of HART devices refer
to the HART Application Guide, created by the HART Communication
Foundation, and their detailed HART specifications. You can download
documents from www.hartcomm.org.)
high demand mode Where the Safety Instrumented Function in the Safety System only performs
its designed function on a demand, and the frequency of demands is greater
than one per year.
hot swap See live insertion.
I
I/O base unit A backplane assembly which holds up to three I/O modules and their
associated termination assembly or assemblies in an AADvance controller.
Part number 9300. See 'I/O module' and 'termination assembly'.

Table of Contents

Other manuals for Rockwell Automation Allen-Bradley AADvance T9110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley AADvance T9110 and is the answer not in the manual?

Rockwell Automation Allen-Bradley AADvance T9110 Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley AADvance T9110
CategoryController
LanguageEnglish

Related product manuals