DISPlay Subsystem FSE
1065.6016.12 6.92 E-16
COMMAND PARAMETERS UNIT COMMENT
[:WINDow<1|2>]
:TRACe<1 to 4>
:MODE
:CWRite
:ANALog
:HCONtinuous
[:STATe]
:SYMBol
:EYE
:COUNt
:PSAVe
[:STATe]
HOLDoff
WRITe | VIEW | AVERage |
MAXHold | MINHold
<Boolean>
<Boolean>
<Boolean>
<Boolean>
DOTS | BARS | OFF
<numeric_value>
<Boolean>
<numeric_value>
--
--
--
--
--
SYM
Vector Signal Analysis
Vector Signal Analysis
Vector Signal Analysis
:DISPlay:FORMat SINGle | SPLit
This command switches the test result display between FULL SCREEN and SPLIT SCREEN.
Example: ":DISP:FORM SPL"
Features: *RST value: SINGle
SCPI: device-specific
Modes: A, VA
:DISPlay:PROGram[:MODE] ON | OFF
This command switches the display between the measuring instrument and the computer function.
Example: ":DISP:PROG ON"
Features: *RST value: OFF
SCPI: device-specific
Modes: A, VA, BTS, MS
This command is only valid in conjunction with Option Computer Function (FSE-B15).
:DISPlay:ANNotation:FREQuency ON | OFF
This command switches the x-axis annotation on or off.
Example: ":DISP:ANN:FREQ OFF"
Features: *RST value: ON
SCPI: conforming
Modes: A, VA, BTS, MS
:DISPlay:LOGO ON | OFF
This command switches the factory logo on the screen on or off.
Example: ":DISP:LOGO OFF"
Features: *RST value: ON
SCPI: device-specific
Modes: A, VA, BTS, MS