FSE MMEMory Subsystem
1065.6016.12 6.141 E-16
:MMEMory:SELect[:ITEM]:TRANsducer:ALL ON | OFF
This command includes all transducer factors and sets in the list of data subsets of a device setting
to be stored/loaded.
Example: ":MMEM:SEL:TRAN:ALL ON"
Features: *RST value: ON
SCPI: device-specific
Modes: A, VA, BTS, MS
This command is an event and therefore has no *RST value assigned.
:MMEMory:SELect[:ITEM]:CVL[:ACTive] ON | OFF
This command includes the active conversion loss table into the list of data subrecords to be stored /
loaded for a device setup.
Example: ":MMEM:SEL:CVL ON"
Features: *RST value: OFF
SCPI: device-specific
Modes: A, VA, BTS, MS
This command is available only in conjunction with option External Mixer Output, FSE-B21.
:MMEMory:SELect[:ITEM]:CVL:ALL ON | OFF
This command includes all conversion loss table into the list of data subrecords to be stored / loaded
for a device setup.
Example: ":MMEM:SEL:CVL ON"
Features: *RST value: OFF
SCPI: device-specific
Modes: A, VA, BTS, MS
This command is available only in conjunction with option External Mixer Output, FSE-B21.
:MMEMory:SELect[:ITEM]:ALL
This command includes all data subsets in the list of data subsets of a device setting to be
stored/loaded.
Example: ":MMEM:SEL:ALL"
Features: *RST value: --
SCPI: device-specific
Modes: A, VA, BTS, MS
This command is an event and therefore has no *RST value assigned.