SENSe Subsystem FSE
1065.6016.12 6.180 E-16
:[SENSe<1|2>:]CORRection:CVL:BIAS <numeric_value>
This command defines the bias current in the Conversion Loss Table.
Example: ":CORR:CVL:BIAS 7mA"
Features: *RST value: -
SCPI: device-specific
Mode: A
Command SENS:CORR:CVL:SEL must be sent prior to this command. This command is only valid
in conjunction with option External Mixer Output, FSE-B21.
:[SENSe<1|2>:]CORRection:CVL:COMMent <string>
This command defines the comment in the Conversion Loss Table.
Parameter: <string>::= Comment of mixer with a maximum of 60 characters
Example: ":CORR:CVL:COMMENT MIXER FOR BAND U’"
Features: *RST value: -
SCPI: device-specific
Mode: A
Command SENS:CORR:CVL:SEL must be sent prior to this command. This command is only valid
in conjunction with option External Mixer Output, FSE-B21.
:[SENSe<1|2>:]CORRection:CVL:DATA <freq>,<level>..
This command defines the reference values of the selected Conversion Loss Tabels. The values are
entered as a result of frequency/level pairs. The frequencies have to be sent in ascending order.
Example: ":CORR:CVL:DATA 1MHZ,-30DB,2MHZ,-40DB"
Features: *RST value: -
SCPI: device-specific
Mode: A
Command SENS:CORR:CVL:SEL must be sent prior to this command. This command is only valid
in conjunction with option External Mixer Output, FSE-B21.
:[SENSe<1|2>:]CORRection:CVL:CLEar
This command deletes the selected Conversion Loss Table.
Example: ":CORR:CVL:CLE"
Features: *RST value: -
SCPI: device-specific
Mode: A
This command is an event which is why it is not assigned an *RST value.
Command SENS:CORR:CVL:SEL must be sent prior to this command. This command is only valid
in conjunction with option External Mixer Output, FSE-B21.