FSE SENSe Subsystem
1065.6016.12 6.205 E-16
:[SENSe<1|2>:]POWer:ACHannel:MODE ABSolute | RELative
This command toggles between absolute and relative measurement.
Example: ":POW:ACH:MODE REL"
Features: *RST value: ABSolute
SCPI: device-specific
Mode: A-F
For the relative measurement the reference value is set to the currently measured channel power by
command POW:ACH:REF:AUTO ONCE.
:[SENSe<1|2>:]POWer:ACHannel:REFerence:AUTO ONCE
This command sets the reference value to the currently measured channel power.
Example: ":POW:ACH:REF:AUTO ONCE"
Features: *RST value: -
SCPI: device-specific
Mode: A-F
This command is an event which is why it is not assigned an *RST value and has no query.
:[SENSe<1|2>:]POWer:ACHannel:PRESet ACPower | CPOWer | OBANdwidth|OBWidth | CN | CN0 |
ADJust
This command selects the type of power measurement and resets the instrument depending on the
selected measurement.
The value ADJust optimizes automatically the settings (span, RBW, VBW and detector) of the
analyzer for the power measurement selected by command
:CALCulate<1|2>:MARKer:FUNCtion:POWer:SELect (see Softkey ADJUST CP SETTINGS).
Example: ":POW:ACH:REF:PRES ACP"
Features: *RST value: -
SCPI: device-specific
Mode: A-F
:[SENSe<1|2>:]POWer:BANDwidth|BWIDth 0 to 100PCT
This command defines the percentage of the power with respect to the total power.
Example: ":POW:BWID 95PCT"
Features: *RST value: 99PCT
SCPI: device-specific
Mode: A-F
This value defines the occupied bandwidth (measurement POW:ACH:PRES OBW).