FSE CALCulate Subsystem
1065.6016.12 6.15 E-16
CALCulate:DLINe Subsystem
The CALCulate:DLINe subsystem checks the display lines in the instrument, i.e., the level, frequency
and time lines (depending on the X-axis) as well as threshold and reference lines.
COMMAND PARAMETERS UNIT COMMENT
CALCulate<1|2>
:DLINe<1|2>
:STATe
:THReshold
:STATe
:CTHReshold
:STATe
:RLINe
:STATe
:FLINe<1|2>
:STATe
:TLINe<1|2>
:STATe
<numeric_value>
<Boolean>
<numeric_value>
<Boolean>
<numeric_value>
<Boolean>
<numeric_value>
<Boolean>
<numeric_value>
<Boolean>
<numeric_value>
<Boolean>
DBM | DB | DEG | RAD | S |
HZ | PCT
DBM | DB | DEG | RAD | S |
HZ | PCT
DBM | DB | DEG | RAD | S |
HZ | PCT
DBM | DB | DEG | RAD | S |
HZ | PCT
HZ
S | SYM
:CALCulate<1|2>:DLINe<1|2> MINimum to MAXimum (depending on current unit)
This command defines the position of the display line.
Example: ":CALC:DLIN -20dBm"
Features: *RST value: - (STATe to OFF)
SCPI: device-specific
Modes: A, VA, BTS, MS
The display lines mark the given level in the display. The units DEG, RAD, S, and HZ are only valid in
conjunction with option Vector Signal Analysis, FSE-B7.
:CALCulate<1|2>:DLINe<1|2>:STATe ON | OFF
This command switches the display line on or off.
Example: ":CALC:DLIN2:STAT OFF"
Features: *RST value: OFF
SCPI: device-specific
Modes: A, VA, BTS, MS