FSE CALCulate Subsystem
1065.6016.12 6.39 E-16
:CALCulate<1|2>:MARKer<1 to 4>[:STATe] ON | OFF
This command switches on or off the currently selected marker. If no indication is made, marker 1 is
selected automatically.
Example: ":CALC:MARK3 ON"
Features: *RST value: OFF
SCPI: device-specific
Modes: A, VA, BTS, MS
:CALCulate<1|2>:MARKer<1 to 4>:AOFF
This command switches off all active markers.
Example: ":CALC:MARK:AOFF"
Features: *RST value: -
SCPI: device-specific
Modes: A, VA, BTS, MS
This command is an event which is why it is not assigned an *RST value and has no query.
:CALCulate<1|2>:MARKer<1 to 4>:TRACe 1 to 4
This command assigns the selected marker (1 to 4) to the indicated test curve.
Example: ":CALC:MARK3:TRAC 2"
Features: *RST value -
SCPI: device-specific
Modes: A, VA, BTS, MS
:CALCulate<1|2>:MARKer<1 to 4>:X 0 to MAX (frequency | sweep time | symbols)
This command positions the selected marker to the indicated frequency (span > 0) or time (span = 0).
Example: ":CALC:MARK:X 10.7MHz"
Features: *RST value: -
SCPI: device-specific
Modes: A, VA, BTS, MS
The unit SYM is available only in the vector signal analysis mode.
:CALCulate<1|2>:MARKer<1 to 4>:X:SLIMits[:STATe] ON | OFF
This command switches between a limited (ON) and unlimited (OFF) search range.
Example: ":CALC:MARK:X:SLIM ON"
features: *RST value: OFF
SCPI: device-specific
Modes: A, VA