Page | 37
Configuring the ZUend position cover closed
1. Starting programming: Press and hold the PROG and ZU (CLOSED) operating
buttons until the two LEDs PROGand ZU(CLOSED) are illuminated.
2. ZU configuring the end position: Use the AUF (OPEN) and ZU (CLOSED)
operating buttons to move the system to the desired end position; the pool should
be covered completely.
3. Finishing programming: Press and hold the PROGand ZU (CLOSED) operating
buttons until PROGLED is no longer illuminated.
Configuring the AUFend position cover open
1. Starting programming: Press and hold the PROG and AUF (OPEN) operating
buttons until the two LEDs PROGand AUF(OPEN) are illuminated.
2. OPEN configuring the end position: Use the AUF (OPEN) and ZU (CLOSED)
operating buttons to move the system to the desired end position; the pool should
be completely open. Make sure that the first profile is flush with the enclosure.
3. Finishing programming: Press and hold the PROG and AUF (OPEN) operating
buttons until the PROGLED is no longer illuminated.