Page | 60
EMERGENCY MODE
Caution! The programmed end positions ‘AUF’ (OPEN) and ‘ZU’ (CLOSED) are deactivated
in emergency mode. The system is moved manually and must be stopped manually. As a
result, there is a risk that the roller shutter could turn over or collide with the wall at the
end of the pool.
Caution! The emergency mode is retained after switching the system off and on again.
Caution! The end positions ‘AUF’ (OPEN) and ‘ZU’ (CLOSED) must be reprogrammed after
activating emergency mode.
Emergency mode was initiated to enable the operation of the swimming pool cover
without the pulse counter as well. The configured/programmed end positions are
ignored!
Activation – steps for activating emergency mode
1. Press and hold the ‘PROG’ button on the control board for 30 seconds.
After this period, the ‘AUF’ (OPEN) and ‘ZU’ (CLOSED) LEDs begin to blink.
2. The swimming pool cover can now be moved manually.
Caution! The emergency mode is retained after switching the system off and on
again.
Deactivation – steps for deactivating emergency mode
3. Press and hold the ‘PROG’ button on the control board for 30 seconds.
4. After this period, the ‘AUF’ (OPEN) and ‘ZU’ (CLOSED) LEDs switch from blinking to
illuminated to indicate that the position memory has been erased.
5. Caution! The two end positions ‘AUF’ (OPEN) and ‘ZU’ (CLOSED)
now need to be reprogrammed.