Model 3095FB Multivariable Transmitter with Modbus Protocol
Modbus Protocol Guide
Page 70 of 79
0032-
0035
ASCII R/W, WP Transmit-
ter info
user-entered tag (U8x8)
0036-
0043
ASCII R/W, WP user-entered descriptor(U8x16)
0044-
0059
ASCII R/W, WP user entered message (U8x32)
0060 Holding
register
R/W, WP Modbus
units codes
for PVs
DP
0061 Holding
register
R/W, WP SP
0062 Holding
register
R/W, WP PT
0063-
0075
Holding
register
R/W, WP Reserved Reserved
0076,
0077
Input reg-
ister
RO PVs
Untrimmed
and Cor-
rected
Counts
DP (U24)
0078,
0079
Input reg-
ister
RO SP (U24)
0080,
0081
Input reg-
ister
RO PT (U24)
0082,
0083
Input reg-
ister
RO ST (U24)
0084-
0115
Input reg-
ister
RO Reserved
0116 Input reg-
ister
RO PV Scaled
Integers
DP
0117 Input reg-
ister
RO SP
0118 Input reg-
ister
RO PT
Input and Holding Registers (includes Floating Point and ASCII registers)
Modbus Access
DESCRIPTION
Address
Address
Type
Attributes
Functional
Area
Data / Control