Reference Manual
00809-0100-4738, Rev DA
May 2006
A-7
Rosemount 3095FB
ORDERING INFORMATION
• Available
— Not available
3095FB 3095FC
Code Product Description
3095F
MultiVariable Transmitter • •
Code Output
B
Process Variable Measurement: Modbus RS-485 • —
C
Process Variable Measurement: Mass Flow and Data Logging: Modbus RS-485 — •
Code Differential Pressure Range
2 0 – 2.5 to 0 – 250 inH
2
O (0 – 6,22 to 0 – 622,7 mbar)
• •
3
0 – 10 to 0 – 1000 inH
2
O (0 – 0,0249 to 0 – 2,49 bar) • •
Code Absolute/Gage Pressure Ranges
3
0.5–8 to 0.5–800 psia (3,447–55,16 to 3,447–5516 kPa) • •
4
0.5–36.26 to 0.5–3,626 psia (3,447-250 to 3,447–25000 kPa) • •
C
0–8 to 0–800 psig (0–55,16 to 0–5516 kPa) ••
D
0–36.26 to 0–3,626 psig (0-250 to 0–25000 kPa) • •
Code Isolator Material Fill Fluid
A
316L Stainless Steel (SST) Silicone • •
B
(1)
Hastelloy C-276 Silicone • •
J
(2)
316L SST Inert • •
K
(1)(2)
Hastelloy C-276 Inert • •
Code Flange Style Material
A
Coplanar CS • •
B
Coplanar SST • •
C
Coplanar Hastelloy C
(2)
••
J
DIN Compliant Traditional Flange SST,
7
/16 - 20 Bolting • •
0
None (Required for Option Codes S3 or S5) ••
Code Drain/Vent Material
A
SST ••
C
(1)
Hastelloy C • •
0
None (Required for Option Codes S3 or S5) ••
Code O-ring
1
Glass-filled TFE • •
Code Process Temperature Input (RTD ordered separately)
0
No RTD Cable (required for 3095FC) ••
1
RTD Input with 12 ft. (3,66 m) of Shielded Cable (intended for use with conduit) • —
2
RTD Input with 24 ft. (7,32 m) of Shielded Cable (intended for use with conduit) • —
3
RTD Input with 12 ft. (3,66 m) of Armored, Shielded Cable (intended for use with conduit) • —
4
RTD Input with 24 ft. (7,32 m) of Armored, Shielded Cable • —
7
RTD Input with 75 ft. (22,86 m) of Shielded Cable (intended for use with conduit) • —
8
RTD Input with 75 ft. (22,86 m) of Armored, Shielded Cable • —
A
RTD Input with 12 ft. (3,66 m) of ATEX Flameproof Cable (typically ordered with Product Certificate code H) • —
B
RTD Input with 24 ft. (7,32 m) of ATEX Flameproof Cable (typically ordered with Product Certificate code H) • —
C
RTD Input with 75 ft. (22,86 m) of ATEX Flameproof Cable (typically ordered with Product Certificate code H) • —
Code Transmitter Housing Material Conduit
A
Polyurethane-covered Aluminum
1
/2–14 NPT • Adapter
E
Polyurethane-covered Aluminum
3
/4–14 NPT — •
B
Polyurethane-covered Aluminum M20 x 1.5 (CM20) • Adapter
C
Polyurethane-covered Aluminum PG 13.5 • Adapter
J
SST
1
/2–14 NPT • —
K
SST M20 x 1.5 (CM20) • —
L
SST PG 13.5 • —