Model 3095FB Multivariable Transmitter with Modbus Protocol
Modbus Protocol Guide
Page 77 of 79
7422 FP register R/W, WP SP calibra-
tion
SP offset
7423 FP register R/W, WP SP slope
7424 FP register R/W, WP SP damping
7425 FP register R/W, WP PT calibra-
tion
PT offset
7426 FP register R/W, WP PT slope
7427 FP register R/W, WP PT damping
7428 FP register R/W, WP User
Entered PT
User Entered PT Value
7429 FP register RO PVs ST
7435 FP register RW PV Scaled
Integers
DP_x1
7436 FP register RW DP_x2
7437 FP register RW SP_x1
7438 FP register RW SP_x2
7439 FP register RW PT_x1
7440 FP register RW PT_x2
*Attributes: R/W = Read/Write, RO = Read Only, WP = Write Protected
**These registers are available at multiple Modbus addresses (see Section 2.3 located in
the Modbus Protocol Guide)
32-bit Floating Point Registers
Modbus Access
DESCRIPTION
Address
Address
Type
Attributes
Functional
Area
Data / Control

Table of Contents