Controller Operation
AYC-E/Q60 Series Installation and Programming Manual 39
Fail Secure Operation
From the moment the REX button is pressed, the door is
unlocked until the Lock Strike Release Time passes. After this
time, the door is locked even if the REX button is not released.
Fail Safe Operation
From the moment the REX button is pressed, the door is
unlocked until the REX button is released, plus the Lock Strike
Release Time. In this case, the Lock Strike Relay only begins its
count down once the REX button is released.
5.8 Secured Intelligent Power Supply
Rosslare’s secured intelligent power supplies are designed for use with
Rosslare's secured standalone access control units, including the
AYC-E/Q60 series. The AYC-E/Q60 units are designed to operate
indoors and are installed within the secured premises. The units must
be used with one of Rosslare’s secured intelligent power supplies,
which provides Lock Strike output and REX input. The AYC-E/Q60 and
the power supply communicate through a proprietary Rosslare
protocol, which provides a secure link between them. This in turn
activates the door lock.
Each power supply unit contains a speaker connection for all sounder
abilities.
For more information, see the
PS-x25T Installation Manual
.