Controller Operation
AYC-E/Q60 Series Installation and Programming Manual 57
4. Perform one of the following:
Enter the PIN code belonging to the user
for whom you wish to add a Secondary
code.
Present the user card belonging to the user for whom you
wish to add a Secondary code.
The left LED flashes red.
If the Primary code entered is not valid, you hear a long beep and
the unit continues to wait for a valid Primary code.
5. Perform one of the following:
Enter the PIN code to be used as the
Secondary code.
Present the user card to be used as the Secondary code.
If the Secondary code is valid, the controller beeps three times
and returns to Normal mode.
If the Secondary code is invalid, the controller sounds a long
beep, and the unit continues to wait for a valid Secondary code
to be entered.
5.9.14 Deleting Primary and Secondary Codes
There are two methods to delete Primary and Secondary codes: the
Standard Method and the Code Search Method.
When deleting a user slot, both the Primary code and the Secondary
code are erased.
It is recommended that a record be kept of added and deleted
users so that it is easier to keep track of which user slots are
empty and which user slots are not.
Red
Orange

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AYC-E60B and is the answer not in the manual?

Rosslare AYC-E60B Specifications

General IconGeneral
BrandRosslare
ModelAYC-E60B
CategoryCard Reader
LanguageEnglish

Related product manuals