Controller Operation
AYC-E/Q60 Series Installation and Programming Manual 47
Table 5: Quick Reference Guide for Auxiliary Mode Setting
Auxiliary
Mode
Auxiliary
Input
Function
Auxiliary
Output
Activated
by
Relay
Auxiliary
Settings
(in seconds)
0 AUX REX Valid code or
AUX REX
N.O. 01 to 99 Aux. relay
release time
00 Aux. relay toggle
1
switch
Valid code N.O. 01 to 99 Aux. relay
release time
00 Aux. relay toggle
2
switch
Star button () N.O. 01 to 99 Aux. relay
release time
00 Aux. relay toggle
3
switch
Tamper event N.C. 01 to 99 Aux. relay
release time
00 Aux. relay tamper
activated
4
switch
Direct shunt N.O.
01 to 99 Shunt time
5 Door Monitor Shunt N.C. 01 to 99 Maximum
shunt time
6 Door Monitor Forced door N.C. 01 to 99 Forced
delay
7 Door Monitor Door ajar N.C. 01 to 99 Ajar delay
8 LED control –
Green
Valid code N.O. 01 to 99 Aux. relay
release time
00 Aux. relay toggle
9 LED control –
Red
Valid code N.O. 01 to 99 Aux. relay
release time
00 Aux. relay toggle