Controller Operation
42 AYC-E/Q60 Series Installation and Programming Manual
5.9.3 Changing Lock Strike Code
The Lock Strike code is mainly used as a method to quickly test the
Lock Strike Relay during installation.
When the first user is added to the controller, the default Lock Strike
code is automatically deleted. Once the code is programmed again, it
is not deleted with the entry of additional user codes.
Lock Strike code does not work in the Secure mode.
Wrong entries return the controller to Normal mode.
Code 0000 erases the Lock Strike code.
The factory default 4-digit Lock Strike code is 2580.
To change the Lock Strike code:
1. Enter Programming mode.
2. Press 1 to enter Menu 1.
The left LED turns red.
3. Enter the new code you wish to set as the
Lock Strike code.
You hear three beeps.
The system returns to Normal mode.
5.9.4 Changing Auxiliary Code
The Auxiliary code is mainly used as a method to quickly test the
Auxiliary Relay during installation.
Auxiliary code does not work in the Secure mode.
Wrong entries return the controller to Normal mode.
Code 0000 erases the Auxiliary code.
The factory default 4-digit Auxiliary code is 0852.
Green
Red
Green
Green

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AYC-E60B and is the answer not in the manual?

Rosslare AYC-E60B Specifications

General IconGeneral
BrandRosslare
ModelAYC-E60B
CategoryCard Reader
LanguageEnglish

Related product manuals