Section 2: Installation & Programming
25238801 2-19
Note that the Fast-Feed information is maintained in memory until it is manually cleared by using the FUNCTION
button. This applies even if another OUT OF SERVICE condition occurs. As an example, if the Fast-Feed Shutdown
condition is entered at 11PM on Saturday and the changer returns to service 10 minutes later and continues to operate
until 3PM on Sunday when it runs out of coins, the display will be flashing “
HOPPERS EMPTY” on Monday morning
at 9AM. When the
FUNCTION button is pressed to clear the empty error, the display will revert to “FF$20 1D10=00
AGO”, which allows you to determine that a Fast-Feed shutdown occurred because the $20 bill count was exceeded
at 11PM Saturday (1 day and 10 hours ago).
Accessing the FAST-FEED Menu
1. Move the PROGRAMMING/NORMAL switch on the bill changer from the NORMAL operation mode to the
PROGRAMMING position.
2. Press the FUNCTION-ERROR RESET button twice. The display should show “PROGRAMMING ----”.
3. Press the
^
button until the display shows “PROGRAMMING 11--”, the press the VALUE button once.
4. Press the
^
button until the display shows “PROGRAMMING 1129”.
5. Press the VALUE button once. The FAST-FEED menu is now active.
Navigating the FAST-FEED Menu
1. When entering the FAST-FEED menu, the display will show “$1 OFF”. The OFF should be flashing. If not,
press the
^
button until the OFF appears. This means that no limit has been placed on any specific number of
$1 bills.
2. Pressing the
^
button will cause the display to show “$1 X, Y, Z”. The X should be flashing. Table 2-5
illustrates the possible values for X, Y, and Z.
Variable Name
X
Y
Z
Table 2-5. XYZ Table
Represents
The number of bills accepted before any
action is taken.
The number of minutes within which no
more than “X” bills can be accepted without
action.
The number of minutes that the bill changer
will be kept OUT OF SERVICE if more
than “X” bills are accepted within “Y”
minutes.
Range
“OFF” or 1 - 15 bills
1 - 15 minutes
1 - 15 minutes
or
“INFINITE”