4-10 25238801
REJECT - LONG VI
Symptom:
The inlet cell was covered for too long a time.
This is a reject message.
The bill was rejected because the VF cell was covered too soon, or the VI cell was covered too long.
The CCC recognized this as a non-valid validation sequence.
If bills are rejected frequently with this code, take the following corrective action:
Corrective Action:
1. Check for small pieces of paper or other foreign objects in the track.
2. The VF flipper may be binding or hanging-up on back rollers.
3. Check for flash or burrs on flipper and back rollers.
4. The VF or VI cell may be giving an intermittent signal. Check the cells for proper switching. If the cells are
OK, check the wiring from the VF cell to the CCC (P4 - Pin 7) for a possible ground to the chassis and VI
cell to the CCC (P4 - Pin 16).
5. If all of previous checks are OK, replace the CCC.
If a bill is left in the transport for five seconds, the bill changer will go into SELF-CLEAR.
REJECT - LONG VF
Symptom:
The flipper cell was blocked for too long a time.
This is a reject message.
The bill was rejected because the VF cell was covered too long.
If this message appears often with good bills, check for tight VF flipper operation, incorrect transport to stacker
alignment, or a nonoperating stacker.
If a bill is left in the transport for five seconds, the bill changer will go into SELF-CLEAR.