Section 4: Troubleshooting
25238801 4-19
REJECT - NO DENOM
Symptom:
Bills are rejected with this code when the validation tests cannot accurately determine the bill’s denomination.
Corrective Action:
1. Replace the transport.
2. Replace the CCC.
REJECT - FAST FEED
Symptom:
The bill is being rejected because its acceptance would exceed the limits established for the Fast-Feed Shutdown
feature. (See Section 2.) The changer will enter the Fast-Feed Shutdown mode as soon as the bill is cleared from
the transport.
REJECT - RETURN SW
Symptom:
The bill return switch was pushed during validation.
Corrective Action:
1. Do not push BILL RETURN switch during validation. Check for loose or shorted wires or a shorted switch.
2. If the switch and wires are OK, replace the CCC.
REJECT - ACCPT OFF
Symptom:
Bill denomination payout was not turned ON.
Corrective Action:
Set the bill changer to accept the rejected denomination.