Motor Power (kW) Net voltage Protection Max. cable length (m) Wire gauge (mm²)
0.45
3x220V 60Hz
3x230V 60Hz
GV2ME07
0-107 1.5
108 - 178 2.5
179 - 285 4
3x380V 60Hz
3x400V 60Hz
GV2ME06
0-294 1.5
295 - 491 2.5
492 - 785 4
0.55
3x230V 50Hz GV2ME08
0-69 1.5
70 - 116 2.5
117 - 185 4
3x230V 50Hz GV2ME07
0-111 1.5
112 - 185 2.5
186 - 297 4
3x400V 50Hz GV2ME07
0-197 1.5
198 - 328 2.5
329 - 525 4
3x400V 50Hz GV2ME06
0-308 1.5
309 - 513 2.5
514 - 821 4
0.75
1x230V 50Hz GV2ME10
0-44 1.5
45 - 73 2.5
74 - 117 4
3x230V 50Hz GV2ME08
0-69 1.5
70 - 116 2.5
117 - 185 4
3x400V 50Hz GV2ME07
0-197 1.5
198 - 328 2.5
329 - 525 4
0.9
1x220V 60Hz
1x230V 60Hz
GV2ME14
0-26 1.5
27 - 44 2.5
45 - 71 4
3x220V 60Hz
3x230V 60Hz
GV2ME10
0-42 1.5
43 - 70 2.5
71 - 113 4
3x380V 60Hz
3x400V 60Hz
GV2ME08
0-117 1.5
118 - 196 2.5
197 - 314 4
1.1
3x230V 50Hz GV2ME10
0-44 1.5
45 - 73 2.5
74 - 117 4
3x400V 50Hz GV2ME08
0-123 1.5
124 - 205 2.5
206 - 328 4
1.32
3x220V 60Hz
3x230V 60Hz
GV2ME14
0-26 1.5
27 - 44 2.5
45 - 71 4
3x380V 60Hz
3x400V 60Hz
GV2ME08
0-117 1.5
118 - 196 2.5
197 - 314 4