54
specifications
electrical
n Input voltage, nominal 110–240 VAC; 50/60 Hz
n Maximum total current draw 0,5 A
physical
n Dimensions (H x W x D) 44,45 x 480 x 282mm (Standard 1U 19” Rack)
n Weight 4,6 kg
environmental
n Elevation (above MSL)
Operating 0 to 3 000 m (0 to 10 000 ft)
Storage 0 to 15 000 m (0 to 50 000 ft)
n Temperature
Operating 0 to 45º C
Storage –15 to 65° C
n Humidity
Operating 0 to 95%, non-condensing
Storage 0 to 95%, non-condensing
output voltages
n Voltages 2 x 12Vdc and 1 x 18Vdc
n Current 2 x 200mA and 1 x 50mA
sensor inputs
Temperature sensors ±3°C
4-20mA sensors ±5%
power backup
n Battery backup time 4 to 6 hours, depending on current drawn on external power supplies