DH4C Advanced Conguration
ITEM DESCRIPTION VALUE [DEFAULT]
Front Default
Display
Select the default monitor display setting: all cameras (# UP) or a single
camera (choose the Channel it is connected to).
[# UP], Channel 01...
Display
Switch
Enable or disable switched display.
Select ON if you want to switch the monitor display from the default setting to
another camera feed based on an Alarm, a Signal, or a specied time, as per
the options detailed below (these parameters are unavailable when Display
Switch is OFF).
[OFF], ON
Switch To When Display Switch is ON, select the camera feed to activate based on the
Alarm, Signal, or Timer setting described below.
You can choose to display a single camera (by Channel number), all connected
cameras (# UP), or to show each active camera feed in sequence (Sequence -
applies only to the Timer option described below).
Channel 01...,
[# UP], Sequence
Switch On Set the trigger type that will activate the camera feed selected in the Switch
To setting and cause it to display in the monitor output.
Then, from the pull-down menu below, select a specic Alarm, Signal, or Timer
setting.
Alarm, [Signal],
Timer
Alarm (Signal
or Timer)
For Alarm or Signal trigger types, choose the specic Alarm/Signal to activate
the selected camera view in the monitor output display when Display Switch
is ON. For example, the ALM1 setting switches monitor output to the view
selected in the Switch To option for the duration of ALM1.
For the Timer trigger type, select the amount of time each active video channel
displays during rotation. For example, 10sec changes channels between valid
camera inputs every 10 seconds.
[ALM 1]...
[Signal 1]...
[3 sec.], 5 sec, 10
sec. 30 sec.