SAGEM-LINK F 288055571-04
Installation and Operation Manual
Page 30/142
Issue 04 : July 2005
Reproduction and communication prohibited without the written permission of Sagem Communication
64 kbit/s Auxiliary Data Channel (AUX3)
The 64 kbit/s auxiliary data channel connector "AUX3" is available in a DB 15 connector on the rear
panel.
This data channel can be configured in a V11 co-directional mode (transmit clock given by the
external equipment) or in a V11 contra-directional mode (transmit clock given by SAGEM LINK F) :
Aux3 Connector pinout is given in Figure 1.24
1
8
9
15
Pin # I/O Signal
1 I Byte Timing Input (-)
9 I Transmit Data Input (-)
2 I Byte Timing Input (+)
10 I/O Transmit Clock (-)
3 O Byte Timing Output (-)
11 I/O Transmit Clock (+)
4 O Receive Data (+)
12 O Receive Clock (+)
5 O Receive Data (-)
13 O Receive Clock (-)
6 O Byte Timing Output (+)
14 - Ground
7 - Ground
15 - NC
8 I Transmit Data Input (+)
Figure 1.24 – Aux3 Data Channel Connector Pinout