SAGEM-LINK F 288055571-04
Installation and Operation Manual
Page 91/142
Issue 04 : July 2005
Reproduction and communication prohibited without the written permission of Sagem Communication
Equipment Settings
Refer to section 3.2.4.6.
ATPC
Refer to section 3.2.4.7.
RSL Switching
This menu is only available for 1+1 space diversity or for 1+1 frequency diversity configurations.
In 1+1 hot standby mode, the RSL switching criteria is not taken in account by the receive switch.
When this menu is selected then the following windows appears :
Click on local or Remote and enter the RSL Switching threshold :
In diversity mode, if the receive level of both receivers are greater than this threshold, then this criteria
is not taken in account by the receive switch.
If the RSL of one of the receivers is below this threshold, then the system selects the receiver with the
best receive level.
Edit Password
This menu allows to modify default passwords. When clicking on this menu, the following windows
appears :