60 • Contents ER-180T Electronic Cash Register AU
Program 100 - PLU Status Programming
1. Turn the control lock to the PGM-Mode.
2. To begin the program, enter 1 0 0, press the SUBTOTAL key.
0 SBTL01
3. Select the PLU or PLUs you wish to program in one of the following ways:
• Enter up to 500 of the PLU and press the PLU key, or
PLU
Enter the PLU#,
up to 500
• Enter the number of the first PLU in a range of PLUs that are to receive the same
setting; press the PLU key. Enter the last PLU number in the range; press the PLU
key.
PLU
Enter the PLU#,
up to 500
Enter the PLU#,
up to 500
PLU
4. Refer to the "PLU” Status Chart" to determine the values for N1 through N8. Enter the
values you have selected, press the X/TIME key. (You do not need to enter preceding
zeros. )
N3 N2 N1 N4 N5 X/TIMEN6 N7 N8
5. To program additional PLUs, repeat from step 3, or press the CASH key to finalize the
program.
CASH
PLU Status Chart
Address Program Option Value
N1
PLU is negative item?
Yes = 1
No = 0
N2
PLU is single item?
Yes = 1
No = 0
N3
PLU is taxable by rate 4?
Yes = 1
No = 0
N4
PLU is taxable by rate 3?
Yes = 1
No = 0
N5
PLU is taxable by rate 2?
Yes = 1
No = 0
N6
PLU is taxable by rate 1?
Yes = 1
No = 0
N7
PLU is override preset?
Yes = 1
No = 0
N8
PLU is preset?
Yes = 1
No = 0
AU default 00000111