Samsung RF263 Series - Tip 9-2. Inspect cooling power

Samsung RF263 Series
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 60/65 -
Tip 9-2. Inspect cooling power ( Must select “Power
Freeze” first)
※ Do not off the power Measure self-diagnosis test
inspection on“TIP 2-4”
Step 1
Touch Display “Energy Saver”+ “Alarm” Key for 8
sec at the same time.
- Touch it until “dingdong” sound occur after all
LEDs blink.
※ When Error appears Move to TIP 2-4
-No problem Inspect Step 2
Step 2 (Comp Operation inspection)
Touch Display “Freezerfor 3set to make
“Power Freeze”.
※ Setting temperature satisfaction and
defrost performance Comp Off.
(If the COMP operate again, off as 8 min.
and operate it)
Inspect the operation of backside Comp.
(Check operation condition using hand
touching Comp)
- If the Comp doesn’t operate See Step 3
- If the Comp operate Inspect Step 6
Step 3 (Inspect Comp Wire )
Inspect the Backside Unit left-side Comp
Wire Connector assembly problem
Inspect OLP & inver wire after disassemble
Comp leftside Relay Cover
If the all things are normal, move the Tip 2-4
comp error inspection click.
Connector
separation
Relay
separation
Next Page

Table of Contents