06-2017
14 / 24
OPERA
CAP. 5
Operation of the machine
EN
1
4
2
3
Fig. 19
4
3
1
2
A
B
Fig. 20
5.13.b - “Water dose” manual program-
ming(Fig. 19)
• Position a container under spout (1).
• Pressbutton(2) ontherst unitonthe leftfor10
seconds,untilitsLEDashes(3).
• Within 30 seconds, press button (4) to dispense hot
water, when the desired quantity is reached, press
button (4) again to stop dispensing.
The dispensed quantity is stored in memory.
5.13.c - Manual temperature programming.
Cup heating plate temperature (Fig. 20).
• Programming the temperature of the cup heating
plateispossibleonlyusingtherstunitontheleft.
• On the rst group on the leftpressthebutton(1)
and keep it pressed, at the same time move forward
the lever (2) and through the buttons (3) and (4) it’s
possible to enable “ON” or disable “OFF” the cup
heatingplateheating;pressthebutton(1)toconrm.
Thecupheatingplatestatusisshownineld“A”of
the group’s display.
• Ifenabledthecupheatingplateheating,intheeld
“A” of the display appears an “ON” writing and is
shown the “050 CUP ON” writing too (50% cup
heating power).
• Press the button (3) to descrease power, on the other
hand press (4) to increase it.
• Toconrmthesetdatapressthebutton(1).