06-2017
CAP. 5
21 / 24
OPERA
Operation of the machine
EN
MAX
°F
°C
MIN
124
3
4
5
1
2
A
1
2
Fig. 22
5.14 - ALARMS (Fig. 22)
• In the event of an alarm, the edge (1) of display (2)
of the unit in alarm turns off and the type of alarm
that has been triggered in shown on display “A”.
5.14.a - Water/coffee is not dispensed by
the unit
• Iftheunitisnotdispensingcoffeeandwhenthelter
holder is removed water is also not dispensed, the
alarmistriggeredandtheLEDashes(1).
5.14.b - Positioning the machine in stand-
by
• If the machine is accidentally put in stand-by, all
displaysturnoffandtheLED(2)oftherstuniton
theleftashes.
• Press LED button (2) to turn the machine on and quit
the stand-by mode.
5.14.c - Filling alarm
• Ifthereareissuesinlling/rellingwaterintheboiler,
after120secondsfromstartofrellingthemachine
issues an alarm, the edge (4) of display (3) turns off
andthelevelgradedscale(5)ashes.
• To clear the alarm, check the water supply line, when
water supply is restored the machine will automati-
cally leave the alarm situation.