06-2017
24 / 24
OPERA
CAP. 5
Operation of the machine
EN
ISSUES CAUSES SOLUTIONS
Coffeeoverowsfromtheedges
ofthelterholder.
Dirt residues are present in the
seatofthelterholder,preventing
coffeefromowingthroughthe
spout.
Unit gasket worn out.
Clogged heads.
Clean.
Replace.
Clean or replace.
Coffee is too cold. Machine not ready. Wait for the temperature to be
reached.
Coffee is not dispensed or is dis-
pensed too slowly.
Insufcientwatersupply.
Clogged lter holder dispensing
hole.
Excessivelynegrinding.
Check the supply line.
Clean the lter holder thoroughly
withspecicdetergentandusinga
toothpick.
Adjust the grinder/dosing device.
The machine does not dispense
steam.
Clogged dispensing nozzle.
Clogged dispensing ducts.
Faulty steam tap.
Clean.
Call the technician to perform a
calcium-removing cleaning.
Call the technical service.
The machine does not dispense
hot water.
Supply tap closed.
Faulty dispensing solenoid valve.
Clogged dispensing ducts.
Open the tap.
Call the technical service.
Call the technician to perform a
calcium-removing cleaning.