-70-
Electrical Adjustment
Group/
Item
Item Name Function Initial Range Note
1 RS232C Baudrate Baud Rate 0 0 - 2 0: 19200bps, 1: 9600bps, 2: 115200bps
2 PJLink Enable PJLink 0 0 - 1 0:Disable 1:Enable
3 Shipping Setting 0 0 - 20 Default set when the value is set to 10.
4 CABLE SW Long Cable 0 0 - 10 n/a
5 PW Debug Command Enable 0 0 - 1
0:Disable (Sanyo Serial Command Eanble)
1: Enable (PW Debug Mode)
6 Device Refresh Disable 0 0 - 1
0:Enable, 1:Disable
No last memory
7 Device Access Disable 0 0 - 1
0:Enable (Normal), 1:Disable
No last memory
8 PJ-Net HangUp Check 0 0 - 1 0: Enable, 1: Disable
20 Projector Time Reset 0 0 - 20
Projector Time is cleared when the value is
set to 10.
21 Lamp Warning Time (NORMAL)
Lamp Life at Normal Mode (Warning Time at
Normal)
500 - 8000
22 Lamp Warning Time (ECO)
Lamp Life at Eco Mode (Warning Time at
Eco)
500 - 8000
23 Lamp Warning Time (HIGH)
Lamp Life at Eco Mode (Warning Time at
High)
500 - 8000
30 Lamp life test enable 0:Disable 1:Enable, for safety test only
31 Lmap On time(for life test) For test purpose
32 Lamp Off time(for life test) For test purpose
33 Lamp total time(for life test) For test purpose
50 Lamp Replacement Display Lamp Warning Display On/Off 1 0 - 1 0: Off, 1: On
51 Filter Warning Display Filter Warning Display On/Off 1 0 - 1 0: Off, 1: On
52 Lamp counter Reset Times Reset Times of Lamp Counter 0 0 - 255 * Read only
53 Filter Counter Reset times Reset Times of Filter Counter 0 0 - 255 * Read only
54 Factory Default Execute Times
Reset Times of Factory Default Set
0
0 - 255 * Read only
55 Motor Stop
Motor Stop 0: Enable, 1: Disable
0
0 - 1
56 Mouse Posiyion (X)
Offset Value of X axis
0
0 - 1024
57 Mouse Position (Y)
Offset Value of Y axis
0
0 - 1024
Group 201 Option (signal)
0 FrameLock Option 1 0 - 1
0: FrameLockOFF at PC signal
1: FrameLockON at PC signal and 47Hz
(Vfreq) ~ Panel frequency of input signal
2 Field Sense Invert Enable 0 0 - 1
Reverse Processing of FLDINVSetting Value
0: Disable - Used FLDINV Setting Value
1: Enable - Used Reversed FLDINV Setting
Value
3
4 Sub Image Enable 1 0 - 1
0:Disable (Service Adjustment Dsiable,
Used all the Center Values
1:Enable (Service Adjustment Enable)
6 Zoom Accelerator Enable 0 0 - 1
0:Zoom Accelerator OFF,
1:Zoom Accelerator ON
No last memory
7 DZoom Reset by Keystone 0 0 - 1
0:Enable (Normal), 1:Disable (Dzoo is not
cancelled even if Keystone is cancelled)
No last memory
8 Stability Count Count Value of V-missing 5 0 - 255
9 Sensivity for Signal Lost (HSYNC)
Only used this value for No Signal
Judgement(Hz)
350 0 - 65535
10 Sensivity for Signal Lost (VSYNC)
Only used this value for No Signal
Judgement(Line)
3 0 - 255
11 Keystone Filter center value
Center value of Keystone Filter
16
0 - 30
Group 210 LampContorl
0 DIMMER_CTRL_LEVEL1
Luminance Level 1 Data for Dimmer: Dim
Level 1 at the less than the Value
0 - 255 Philips 200W
1 DIMMER_CTRL_LEVEL2
Luminance Level 2 Data for Dimmer: Dim
Level 2 at the less than the Value
0 - 255
2 DIMMER_CTRL_LEVEL3
Luminance Level 3 Data for Dimmer: Dim
Level 3 at the less than the Value
0 - 255
3 DIMMER_CTRL_LEVEL4
Luminance Level 4 Data for Dimmer: Dim
Level 4 at the less than the Value
0 - 255
4 DIMMER_CTRL_LEVEL5
Luminance Level 5 Data for Dimmer: Dim
Level 5 at the less than the Value
0 - 255
5 DIMMER_CTRL_LEVEL6
Luminance Level 6 Data for Dimmer: Dim
Level 6 at the less than the Value
0 - 255
6 DIMMER_CTRL_LEVEL7
Luminance Level 7 Data for Dimmer: Dim
Level 7 at the less than the Value
0 - 255
7 DIMMER_CTRL_LEVEL8
Luminance Level 8 Data for Dimmer: Dim
Level 8 at the less than the Value
0 - 255
8 DIMMER_CTRL_LEVEL9
Luminance Level 9 Data for Dimmer: Dim
Level 9 at the less than the Value
0 - 255
9 DIMMER_CTRL_LEVEL10
Luminance Level 10 Data for Dimmer: Dim
Level 10 at the less than the Value
0 - 255