Safety Instructions
3
Note on cable quality:
CE conformity is only guaranteed with well shielded cables�
The shielding braid of the cable must be made of metal with at least 80% coverage and also covered with metal foil
as much as possible�
The shielding on both sides on the full metal or metalized connector casing, as well as on the casing inlet, must be
high-frequency compliant and have a flat design�
3
You can only turn off power to the device by pulling the plug or disconnecting the power cord, or by unscrewing the four-
pin plug at the DC supply cable for the balance�
3
Only use a lightly-moistened cloth for cleaning� See “Care and Maintenance" for cleaning the device� Do not
compromise the IP protection of the balance�
3
Do not open the balance housing� If the seal is broken, this will result in forfeiture of all claims under the
manufacturer’s warranty� The device may only be opened by specialized personnel trained by Sartorius�
3
Disconnect the balance from the wall outlet prior to moving the device�
3
Avoid condensation damage to the device� When the balance is turned on,
condensation build-up is not possible� If the device is moved from a cool environment to a warm environment, you
must allow the device to acclimatize for approx� 2 hours before connecting to the power supply�
Hazards at the Place of Installation and During Operation
3
Avoid generating static electricity and establish potential equalization� A 10 kOhm ground is used when connecting
the balance to the power supply�
Disconnecting the ground conductor is not permitted�
3
Models with a separate electronics module (e� g� MSE6�6/3�6/2�7 225S/P and 125P): Do not replace the electronics
module�
Replacing with, e� g� models of the ME/SE series will damage the device�
3
Exercise caution to avoid glass breakage�
There is a danger of lacerations or cuts caused by sharp edges on glass or metal (contact springs), particularly when
removing or replacing the glass draft shield panels; during cleaning; if a glass sample container breaks, or when
modifying the balance hardware configuration�
3
Make sure all equipment operators have received proper instructions when working with hazardous or toxic materials�
Failure to follow correct handling procedures can result in breakage of parts or spillage of liquids or other substances�
Make sure the necessary protective clothing or equipment is worn, such as protective gloves, clothing, eyewear� All safety
regulations applicable in the laboratory must be observed�
3
Exercise caution to avoid squeezing or crushing fingers when
– Operating the electronic draft shield
– Removing or installing the panels
– Adjusting the display
3
Do not expose the device to aggressive chemical vapors or to unnecessarily extreme temperatures, moisture, shocks,
or vibration�
3
The device should be setup in areas away from equipment or devices that have strong magnetic properties�
Extreme electromagnetic fields from electrical lines should also be avoided�
Cubis MSE Operating Instructions 5

Other manuals for Sartorius Cubis Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sartorius Cubis Series and is the answer not in the manual?

Sartorius Cubis Series Specifications

General IconGeneral
DisplayColor touch screen
Readability0.01 mg to 1 g
InterfacesUSB, Ethernet, RS-232
CalibrationInternal and external
HousingDie-cast aluminum
Response TimeVaries by model
Pan SizeVaries by model
Operating Temperature10°C to 30°C
ComplianceGLP
Power Supply100 – 240 V, 50/60 Hz
CapacityVaries by model (up to 64 kg)
RepeatabilityVaries by model
LinearityVaries by model