Sample Printouts
For details on the individual information
blocks, see “Configuring Printouts”, above.
For details on configuring the header lines,
refer to the “Basic Application Programs”
manual for the Combics 3.
Weighing Application
There is no data for the “initialization
data” block. If this block is enabled for
the printout, a blank line is output.
With weighing platform serial number:
HEADER LINE 1
HEADER LINE 2
14.01.2002 09:43
--------------------
Ser.no. 80705337
G# + 1.402 kg
T + 0.200 kg
N + 1.202 kg
--------------------
Counting Application
The “Initialization data” block contains the
reference sample quantity and reference
piece weight. The “Results” block contains
gross, net and tare weights, as well as the
calculated piece count.
HEADER LINE 1
HEADER LINE 2
14.07.2002 09:43
--------------------
nRef 10 pcs
wRef + 0.035 kg
G# + 1.402 kg
T + 0.212 kg
N + 1.190 kg
Qnt 34 pcs
--------------------
Neutral Measurement Application
The “Initialization data” block contains the
reference sample quantity and reference
weight. The “Results” block contains
gross, net and tare weights, as well as the
calculated piece count.
HEADER LINE 1
HEADER LINE 2
14.07.2002 09:43
--------------------
Ref 2 o
wRef + 1.200 kg
G# + 14.700 kg
T + 0.300 kg
N + 14.400 kg
Qnt 12 o
--------------------
Weighing in Percent Application
The “Initialization data” block contains the
reference percentage and reference weight.
The results block shows gross, net and tare
weights, as well as the percentage, which
is shown as either the loss or the residual
amount.
Percentage = residue:
HEADER LINE 1
HEADER LINE 2
14.07.2002 09:43
--------------------
pRef 100 %
Wxx% + 2.100 kg
G# + 1.859 kg
T + 0.200 kg
N + 1.659 kg
Prc 79 %
--------------------
Percentage = loss:
:
:
D21%
--------------------
Checkweighing Application
The “Initialization data” block contains
the nominal, minimum and maximum
weights. The “Results” block always
contains the gross, net and tare weights.
The other results can be displayed in one
of two ways:
Result = Weight:
The deviation from the nominal weight
is given both as a percentage and as an
absolute (weight) value, whether the
result lies within the “OK” range or not.
Result = Threshold status:
If the result lies within the “OK”
range, the printout shows the deviation
from the nominal weight both as a
percentage and as an absolute (weight)
value, just as in the “Weight” printout
mode described above. If the result
is outside the “OK” range, the last line
of the printout indicates the status
as follows:
Result in “OK” range; “Weight” or
“Threshold” printout:
HEADER LINE 1
HEADER LINE 2
14.07.2002 09:43
--------------------
Setp + 1.300 kg
Min + 1.235 kg
Max + 1.365 kg
G# + 1.312 kg
T + 0.000 kg
N + 1.312 kg
Lim + 0.92 %
W.Diff+ 0.012 kg
--------------------
Result outside “OK” range; “Weight”
printout:
:
:
Lim - 7.69 %
W.Diff- 0.100 kg
--------------------
Result outside (under) “OK” range;
“Threshold” printout:
:
:
Stat LL
--------------------
Result outside (over) the “OK” range;
“Threshold” printout:
:
:
Stat HH
--------------------

Other manuals for Sartorius CW3P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sartorius CW3P and is the answer not in the manual?

Sartorius CW3P Specifications

General IconGeneral
BrandSartorius
ModelCW3P
CategoryAccessories
LanguageEnglish

Related product manuals