Appendix D Parameters for Data Monitoring and Logging
PM135 Powermeter Series 161
Designation
Description
TOU REG2
Billing TOU Energy Register #2
E, EH
REG2 TRF1
Tariff #1 register
REG2 TRF2
Tariff #2 register
REG2 TRF8
Tariff #8 register
TOU REG3
Billing TOU Energy Register #3
E, EH
REG3 TRF1
Tariff #1 register
REG3 TRF2
Tariff #2 register
REG3 TRF8
Tariff #8 register
TOU REG4
Billing TOU Energy Register #4
E, EH
REG4 TRF1
Tariff #1 register
REG4 TRF2
Tariff #2 register
REG4 TRF8
Tariff #8 register
TOU MAX DMD REG1
Billing TOU Maximum Demand Register #1
E, EH
REG1 TRF1 MD
Tariff #1 maximum demand
REG1 TRF2 MD
Tariff #2 maximum demand
REG1 TRF8 MD
Tariff #8 maximum demand
TOU MAX DMD REG2
Billing TOU Maximum Demand Register #2
E, EH
REG2 TRF1 MD
Tariff #1 maximum demand
REG2 TRF2 MD
Tariff #2 maximum demand
REG2 TRF8 MD
Tariff #8 maximum demand
TOU MAX DMD REG3
Billing TOU Maximum Demand Register #3
E, EH
REG3 TRF1 MD
Tariff #1 maximum demand
REG3 TRF2 MD
Tariff #2 maximum demand
REG3 TRF8 MD
Tariff #8 maximum demand
TOU MAX DMD REG4
Billing TOU Maximum Demand Register #4
E, EH
REG4 TRF1 MD
Tariff #1 maximum demand
REG4 TRF2 MD
Tariff #2 maximum demand
REG4 TRF8 MD
Tariff #8 maximum demand
1
In 4LN3, 3LN3 and 3BLN3 wiring modes, the voltages will be line-to
neutral; for any other wiring mode, they will be line-to-line voltages.
2
The value is calculated as a relation of the maximum deviation of
phase values from a 3-phase average value to a 3-phase average.
NOTE
Designations of some enginering demands and billing energy and demand
registers are shown using a short name notation available in PAS V1.4. By
default, PAS uses long names compatible with older versions of PAS. You
can select a desired notation from the Tools/Options/Preferences tab.
PAS does not allow to store data in files using different data names. If you
have a file uploaded with a previous version of PAS using long data
names, either continue using long data names, or store data in a new file.
See table below for a list of parameters with short and long names.