Section 5. Configuration Commands
SATO CX400 PN 9001106 Rev. A Page 5-9
Serial Interface Parameters
COMMAND STRUCTURE <ESC>CRaaaaa,b,c,d
aaaaa = Baud rate, 9600, 19200, or 38400 bps
b= Parity
N = None
O = Odd
E = Even
c = Number of data bits, 7 or 8
d = Number of stop bits, 1 or 2
Example: <ESC>CR9600,N,8,1
Placement: Separate data stream sent to printer
Default: 9600,N,8,1
COMMAND FUNCTION To set the operating parameters of the RS232 Inferface.
INPUT TO PRINTER <ESC>A
<ESC>CR9600,N,8,1
<ESC>Z
PRINTER OUTPUT
There is no printer output as a result of this command.
SPECIAL NOTES 1. The settings must match those of the host system. The
RS232 settings of the printer may be verified by printing a
Test Label.
2. A two second delay after this command must separate this
command and any other command sent to the printer or the
following command may be lost.