Section 5. Configuration Commands
SATO CX400 PN 9001106 Rev. A Page 5-3
Calibrate Sensor
COMMAND STRUCTURE <ESC>CA
Example: <ESC>CA
Placement: Separate data stream sent to printer
Default: There is no default for this command.
COMMAND FUNCTION To calibrate the label sensor for media and ribbon combinations..
INPUT TO PRINTER <ESC>A
<ESC>CA
<ESC>Z
PRINTER OUTPUT There is no output as a result of this command. It causes the printer to
feed approximately 6 inches of media while the characteristics of the
label backing or eye-mark are measured.
SPECIAL NOTES 1. The sensor is calibrated for the currently selected sensor type.
2. This setting is saved in non-volatile memory.
3. The sensor must be recalibrated whenever the sensor type is
changed or a label detect failure occurs
4. When calibrating the sensor for Thermal Transfer printing, the rib-
bon must be installed in the printer.