Receiverhead
10. Power
TheLEDislocatedattheoppositeendoftheconnector.Theone
atthetopis thepowersupply,LEDstatus.WhentheSIMmodule
isunderpowerandthereceiverisconnected,thisLEDis“on”.
11. Presence
BelowthePo werLED,twoLEDsare presentoneitherside
ofthe
centerlineofthephotocell.Whenthephotocelldetectsavalid,
object according to the minimum detectable dimension, both
LEDs are “on”.These LEDs always followthe state of the green
LED(presence)locatedontheSIM‐Pmo dule.
12. Each cell state
Belowthepo wer presenceLED,tworowsof
LEDsarelocatedon
each side of the center line of the window. When a cell is
obstructed,theequivalentLEDlocatedoneachsideofthiscellis
set“on”.A total of64LEDsarepresent.According to thescan
precision,moreorlessLEDsareset“on”.In
coarseresolution,16
arefunctioning, inmedi umresolution32and,inhighresolution,
all 64 LEDs are functioning.Unlike the SIM‐P’s LEDs, the half‐
intensity level doesnot existin the receiver to indicate that the
minimumdetectableobjecthasnotbeenreached.Ifthiswerethe
case,some
LEDsare“on”,butthetwopresenceLEDsarenot“on”
indicating that the photocelldetects something that is less than
theminimumdetectabledimension.Whenacelliscancelled,the
corresponding LED will flash 2 times per second until a reset
cancellationisperformed,orthecancellationisdisabled.